Ceramic-Lined Reducer Drawing Checklist

2026-11-18
Latest company news about Ceramic-Lined Reducer Drawing Checklist

Ceramic-Lined Reducer Drawing Checklist

Suppose a replacement reducer drawing shows Ø300 mm at the small end. Follow the dimension arrows. Do they land on the bare steel wall or on the ceramic surface? The flange can match the existing bolt pattern in either case. A difference in the finished bore can still leave a step inside the joint.


On a large transition for a cement raw meal line, ELACERA reviewed the inlet, outlet, and taper profile, along with the required finished bore, before fitting the alumina tiles. When replacing a reducer in an existing line, extend the section view beyond both ends. That puts the new ceramic lining and the pipe openings it must meet on the same drawing.


Mark three diameters at each connection

DN identifies the nominal size under ISO 6708. [1] On a ceramic-lined reducer drawing, record the actual steel bore, the required finished bore and the clear bore of the existing pipe at each mating face.

Worked example. Assume straight, circular sections at both ends. The ceramic tiles and bonding layer together take up 10 mm per side, measured radially. The dimensions below are illustrative.

Dimension at the joint

A · Large end

B · Small end

Steel shell bore before lining

Ø420 mm

Ø320 mm

Finished reducer bore after lining

Ø400 mm

Ø300 mm

Clear bore of the existing pipe at the mating face

Ø400 mm

Ø300 mm

At the small end, the lining takes up 20 mm across the diameter. A Ø300 mm steel bore would leave a Ø280 mm finished opening. If the drawing calls for a Ø300 mm finished bore at that joint, the same lining build requires a Ø320 mm steel bore at that end.


If you measure an old pipe mouth that has worn in service, mark the dimension “as found” and show where you took it. Check the intended bore against the approved drawing or an unworn section before setting the replacement dimensions.


Define the installation length

On a flanged reducer, show which two faces define the face-to-face length. If the site measures the gap between two fixed flanges, record it separately as the available installation gap. Show any connecting spool and allow for the installed gaskets before assigning a length to the reducer. For a weld-end reducer, identify the two end planes used for the overall length.


Show which surface must line up

On a flat-bottom eccentric reducer, mark the surface that governs the installation elevation. Is it the underside of the steel shell or the bottom of the finished ceramic bore? If the powder needs a continuous floor at the joint, show the bottom of both mating bores against the same elevation reference.


Mark the offset between the two centerlines and add an arrow for the actual material flow. For fixed flanges, show the bolt-hole orientation relative to the installed top of the fitting. Label which end each view is taken from.


Planning a replacement? Send ELACERA your old reducer drawing or a sketch of the two connections, with the flow direction and any dimensions you already have. We can help identify what still needs measuring before quoting.